Neargrid
Boost
The quiet powerhouse in the Neargrid family provides renewable power for even the most demanding construction sites - enough to power up to three tower cranes continuously. Where the grid stops, Neargrid begins.
Always produce. Always Build.
A weak grid connection should never determine your progress. The Neargrid Boost keeps your construction site running-day and night, at every peak moment. The battery system acts as a smart microgrid that captures peak consumption and guarantees a stable voltage. So your tower cranes operate without interruption, even where the grid fails. No downtime, no loss of time : only continuity.
Your construction site produces without you having to think about it.
Maximum output
Microgridon your construction site.
The Neargrid Boost has enough with a three-phase mains connection of 16 A to power 1 tower crane.
Autonomy
Fully integrated electrical protection.
).
In the event of a power failure on the grid, the Neargrid Boost as UPS provides power to the tower crane - uninterrupted - for another four hours.
Customized
Always informed, always current.
Our technology is fully aligned with the construction process. Neargrid focuses on the classic pain points construction sites face.
Specifications
boost 80
boost 100
boost 120
boost 140
boost 160
Application
Boost
Peak shaving, cycling, storage renewables
Peak shaving
1 tower crane
45 kW
55 kW
75 kW
95 kW
110 kW
2 tower cranes
-
-
55 kW
65 kW
75 kW
3 tower cranes
-
-
35 kW
-
55 kW
Power supply to the construction site
nominal power
80 kVA
100 kVA
120 kVA
140 kVA
160 kVA
Peak power
120 kW
150 kW
180 kW
210 kW
240 kW
output voltage
400 V
400 V
400 V
400 V
400 V
descending groups for tower crane
1 output 125A CEE or 160A bolted
3 departures: 2x160A and 1x250A bolted
other descending groups
1 output 63A CEE
4 outputs: 2x 63A CEE and 2x32A CEE
Battery
battery capacity
40 kWh
40 kWh
80 kWh
80 kWh
80 kWh
Type
AGM Pure lead
Top Up
input voltage
3x400, 3x230
3x400, 3x230
3x400, 2x230
3x400, 2x230
3x400, 2x230
input current
max 32A, max 55A
max 32A, max 55A
max 63A, max 105A
max 63A, max 105A
max 63A, max 105A
Solar
10 kW - AC
10 kW - AC
20 kW - AC
20 kW - AC
20 kW - AC
Genset
Active genset control
Topology
Microgrid forming
Security
RCD protection on tower crane outlets
Yes, on-site adjustable
Electronically adjustable short-circuit and overcurrent protection
yes, remote and on-site adjustable, C-curve, measured
Selective protection
Yes
Yes
Yes
Yes
Yes
Mechanical
dimensions (L x W x h)
2.1 m x 1.5 m x 2.3 m
weight
3.2 tons
3.2 tons
4.2 tons
4.2 tons
4.2 tons